Compression fittings

In order to achieve a proper fit, please follow the steps described below:

 

Ø 20 mm – Ø 40 mm

Cut the pipe at 90° angle, chamfer, lubricate the pipe end and the o-ring.

Slacken the nut and slide the pipe through the o-ring and the stop.

Thread the nut until it’s hand-tight.

Ø 50 mm – Ø 110 mm

Prep the pipe. Slide on the compression nut, grip ring and o-ring.

Slide the pipe into the fitting until it reaches the stop. Insert the o-ring and the grip ring; thread the nut.

Using a crescent wrench, thread the nut until it’s tight.

Attention! Keep all elements clean and free of any debris.