Assembly instruction of compression fittings :
In order to ensure the quality of the connection, assembly of commpression fittings shall be carried out as follows:
| Ø 20 mm - Ø 50 mm |
| Cut the pipe at 90º to its centreline using a pipe cutter, moisten end of pipe by water and oap. |
||
| Slacken the ring nut and insert the pipe until the o-ring and internal pipe slide stop. | ||
| Hand Tighten the ring nut. |
||
| Ø 63 mm - Ø 110 mm |
| After preparing pipe ends, unscrew the fitting, then put all internal components: the ring nut, rip ring and the o-ring. |
||
| Push the pipe in to the fitting until it reaches the stop. Insert the o-ring and the collet in to he pipe. |
||
| Tighten with a strap/chain wrench in order to complete the assembly. |
Note! The pipes and connectors shall be kept clean during assembly.